3M 7655-S-4-TI Cold Shrink 4 Skirt Termination
Product image thumbnail 0
Product image thumbnail 1
$317.78/ea
Usually ships within 8 to 12 Days
ea
Adding...
Already a Customer? Log in to view your pricing
Manufacturer 3M
Mfg Catalog # 7655-S-4-TI
North Coast Part # 1009879

Features

  • Provides a void-free seal to jacketed concentric neutral and concentric neutral power cables
  • High dielectric-constant material regulates the distribution of electric field stress
  • 3M™ Cold Shrink QT III 7640 S & 7650 S Series Termination Kit includes a skirted termination with a jumper wire top insulator. It ensures a pliable, tight seal for jacketed concentric neutral and concentric neutral power cables. The conjunction of high dielectric constant material and sealing compounds allows the termination to withstand voltages of 5 to 25/28 kV.
  • Suitable for outdoor applications
  • Integrated, jumper wire-top insulator and step-core design allows for easier installation, while sealing compounds provide constant radial pressure

Specifications

  • 3M ID: 80611200116
  • Agency Approvals: IEEE
  • Brand: 3M™
  • Breakout Boot: No
  • Cable Insulation Outside Diameter Range: 1.05-1.80 in
  • Cable Insulation Outside Diameter Range (Metric): 26.7-45.7 mm
  • Cable Shielding: Concentric Neutral (CN) || Jacketed Concentric Neutral (JCN)
  • Case Quantity: 1
  • Compatible Lug: QL2-A-350-750 || QL2-A-4/0-600
  • Conductor Size by Voltage: (5 kV) 700-1500 kcmil, (8 kV) 600-1250 kcmil, (15 kV) 500-1000 kcmil, (25/28 kV) 250-800 kcmil
  • Conductor Sizes: 1000 kcmil || 1250 kcmil || 1500 kcmil || 250 kcmil || 300 kcmil || 350 kcmil || 400 kcmil || 450 kcmil || 500 kcmil || 600 kcmil || 700 kcmil || 750 kcmil || 800 kcmil || 900 kcmil
  • Family: QT-III
  • Indoor/Outdoor: Outdoor Skirted
  • Insulation Level: 100% || 133%
  • Insulation Outer Diameter (Imperial): 1.05 in || 1.06 in || 1.07 in || 1.08 in || 1.09 in || 1.1 in || 1.11 in || 1.12 in || 1.13 in || 1.14 in || 1.15 in || 1.16 in || 1.17 in || 1.18 in || 1.19 in || 1.2 in || 1.21 in || 1.22 in || 1.23 in || 1.24 in || 1.25 in || 1.26 in || 1.27 in || 1.28 in || 1.29 in || 1.3 in || 1.31 in || 1.32 in || 1.33 in || 1.34 in || 1.35 in || 1.36 in || 1.37 in || 1.38 in || 1.39 in || 1.4 in || 1.41 in || 1.42 in || 1.43 in || 1.44 in || 1.45 in || 1.46 in || 1.47 in || 1.48 in || 1.49 in || 1.5 in || 1.51 in || 1.52 in || 1.53 in || 1.54 in || 1.55 in || 1.56 in || 1.57 in || 1.58 in || 1.59 in || 1.6 in || 1.61 in || 1.62 in || 1.63 in || 1.64 in || 1.65 in || 1.66 in || 1.67 in || 1.68 in || 1.69 in || 1.7 in || 1.71 in || 1.72 in || 1.73 in || 1.74 in || 1.75 in || 1.76 in || 1.77 in || 1.78 in || 1.79 in || 1.8 in
  • Insulation Outer Diameter (Metric): 11.684 mm || 26.67 mm || 26.924 mm || 27.178 mm || 27.432 mm || 27.686 mm || 27.94 mm || 28.194 mm || 28.448 mm || 28.702 mm || 28.956 mm || 29.21 mm || 29.464 mm || 29.718 mm || 29.972 mm || 30.226 mm || 30.48 mm || 30.734 mm || 30.988 mm || 31.242 mm || 31.496 mm || 31.75 mm || 32.004 mm || 32.258 mm || 32.512 mm || 32.766 mm || 33.02 mm || 33.274 mm || 33.528 mm || 33.782 mm || 34.036 mm || 34.29 mm || 34.544 mm || 34.798 mm || 35.052 mm || 35.306 mm || 35.56 mm || 35.814 mm || 36.068 mm || 36.322 mm || 36.576 mm || 36.83 mm || 37.084 mm || 37.338 mm || 37.592 mm || 37.846 mm || 38.1 mm || 38.354 mm || 38.608 mm || 38.862 mm || 39.116 mm || 39.37 mm || 39.624 mm || 39.878 mm || 40.132 mm || 40.386 mm || 40.64 mm || 40.894 mm || 41.148 mm || 41.402 mm || 41.656 mm || 41.91 mm || 42.164 mm || 42.418 mm || 42.672 mm || 42.926 mm || 43.18 mm || 43.434 mm || 43.688 mm || 43.942 mm || 44.196 mm || 44.45 mm || 44.704 mm || 44.958 mm || 45.212 mm || 45.466 mm || 45.72 mm
  • Insulation Rejacketing: No
  • Jacket Outside Diameter Range: 1.39-2.40 Inch
  • Jacket Outside Diameter Range (Metric): 35.3-61.0 mm
  • Lug/Stem Connector Included in Kit: No
  • Maximum Installed Length: 12.25 in
  • Number of Conductors: 1
  • Number of Skirts: 4
  • Voltage: 15 kV || 25 kV || 5 kV || 8 kV

Overview

UPC 05400743412
GTiN 00054007434122
Type QT-III
Conductor Size 1000 MCM; 1250 MCM; 1500 MCM; 250 MCM; 300 MCM; 350 MCM; 400 MCM; 450 MCM; 500 MCM; 600 MCM; 700 MCM; 750 MCM; 800 MCM; 900 MCM
Applications Outdoor
Cable Type Concentric Neutral (CN); Jacketed Concentric Neutral (JCN)
Family Brand Name 3M
Voltage 5 kV
Indoor Outdoor Outdoor Skirted

Your Product Lists

Log In or register for an account to gain access to the product groups feature!

You can create lists of products for regular needs, special projects, even use one as a wishlist.

Your Part Numbers

Log In or register for an account to assign your company part numbers to products!

No more memorizing or cross-referencing! Map your company's internal part numbers to items, then use your part numbers for searching and ordering.