Product image for PROSOFT 5228-MNET-HART MODBUS TCP/IP TO ANALOG HART - 8 CHANNEL
Image thumbnail 0
Image thumbnail 1

Email

PROSOFT 5228-MNET-HART MODBUS TCP/IP TO ANALOG HART - 8 CHANNEL

Manufacturer: Prosoft Technology, Inc. | Catalog # 5228-MNET-HART | North Coast Part # 751325

$3,708.10 /ea
ea
Log in or register to view your price, purchase history, and more!
Next Day Delivery not avail / contact sales for lead times & return policy
The HART Analog Input Gateway provides a clean way to integrate HART Analog instruments with existing controller platforms on a Modbus TCP/IP network. The gateway works well for field applications where it can be installed closer to HART instrument, saving on copper cable and installation costs. The gateway also saves valuable rack space for other in-chassis options. The gateways provide extremely fast channel update times (all channels updating simultaneously in 67 ms) making the HART Analog Input Gateway ideal for applications where high speeds and point-to-point connectivity are required. These gateways are available in 4 and 8 Analog input channel options.

Manufacturer Information

Brand
Prosoft Technology

General Product Info

12-Digit UPC
992231002376
Applications
  • The MNET-RIO modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate a Remote I/O device into a system. The Modbus TCP/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the Remote I/O device support, the module provides a very powerful interface to the many Remote I/O devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially the Manufacturing, Oil and Gas, Electrical Power and Food Processing.
Internal Database
  • The ProLinx module contains an internal database that consists of areas for application data, status information, and configuration information.
  • The internal database is shared between all ports on the module and is used as a conduit to pass information from a device on one network to one or more devices on another network.
Configuration Data Area
  • This area contains module configuration information such as port configuration, network information, and command configuration. This configuration file is downloaded to, or uploaded from, this area.
Application Data Area
  • The data area is used to store and retrieve data by the protocol drivers and for data exchange between protocols. The database is used as a source for write commands to remote devices and holds data collected from the remote devices. Commands defined in the configuration file (stored in the configuration data area) control how the data is to be handled in the database.
Status Data Area
  • This area is used to store error codes, counters, and port status information for each port.