Fluke Electronics FLUKE-117 600 VAC/VDC Electrical Multimeter
Product image thumbnail 0
Product image thumbnail 1
Product image thumbnail 2
Product image thumbnail 3
Product image thumbnail 4
$283.14/ea
ea
Adding...
Already a Customer? Log in to view your pricing
Manufacturer Fluke
Mfg Catalog # FLUKE-117
North Coast Part # 340843

Features

Key Features

  • Non-contact voltage detection
  • AutoVolt automatic AC/DC voltage selection
  • Prevent false readings caused by ghost voltage with selectable low-impedance mode

Product Overview

  • The Fluke 117 Electricians Multimeter includes integrated non-contact voltage detection and Auto Volts and LoZ functions to help get the job done faster and prevent false readings caused by ghost voltage. It is a compact true-rms meter for demanding applications like commercial buildings, hospitals, and schools.
  • The Fluke 117 provides Min/Max/Average readings and measures frequency and capacitance. Plus, its easy-to-use interface can save you time and enable you to move from job to job more quickly.

Other Useful Features

  • Features true-rms capabilities for accurate measurements on non-linear loads
  • Accurate, easy-to-use multimeter with integrated VoltAlert™ technology for fast, go/no go non-contact voltage detection
  • Features AutoVolt automatic AC/DC voltage selection
  • Provides low input impedance to help prevent false readings due to ghost voltage
  • Presents a large white LED backlight for working in poorly lit areas
  • Measures 10 A (20 A overload for 30-seconds)
  • Measures resistance, continuity, frequency, and capacitance
  • Provides Min/Max/Average to record signal fluctuations
  • Comes with an holster with probe holders for easy storage
  • Fits into optional ToolPak™ magnetic hanger for hands-free operation
  • CAT III 600 V safety rated
  • A large white LED backlight to improve measurement visibility in poorly lit areas

Additional Features

  • 1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.

Includes

  • 4 mm silicone test lead set
  • Holster
  • User manual

Specifications

  • Maximum voltage between any terminal and earth ground: 600 V
  • Surge protection: 6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2
  • Fuse for A input: 11 A, 1000 V FAST Fuse (Fluke PN 803293)
  • Display: Digital: 6,000 counts, updates 4 per second
  • Bar graph: 33 segments, updates 32 per second
  • Operating temperature: -10°C to +50°C
  • Storage temperature: -40°C to +60°C
  • Battery type: 9 volt Alkaline, NEDA 1604A / IEC 6LR61
  • Battery life: 400 hours typical, without backlight

Accuracy Specifications

  • DC millivolts Range/resolution: 600.0 mV / 0.1 mV
  • DC millivolts Accuracy: ±([% of reading] + [counts]): 0.5% + 2
  • DC volts Range/resolution: 6.000 V / 0.001 V60.00 V / 0.01 V600.00 V / 0.1 V
  • DC volts Accuracy: ±([% of reading] + [counts]): 0.5% + 2
  • Auto volts Range/resolution: 600.0 V / 0.1 V
  • Auto volts Accuracy: 2.0% + 3 (DC, 45 Hz to 500 Hz)4.0% + 3 (500 Hz to 1 kHz)
  • AC millivolts¹ True RMS Range/resolution: 600.0 mV / 0.1 mV
  • AC millivolts¹ True RMS Accuracy: 1.0% + 3 (DC, 45 Hz to 500 Hz)2.0% + 3 (500 Hz to 1 kHz)
  • AC volts¹ True RMS Range/resolution: 6.000 V / 0.001 V60.00 V / 0.01 V600.0 V / 0.1 V
  • AC volts¹ True RMS Accuracy: 1.0% + 3 (DC, 45 Hz to 500 Hz)2.0% + 3 (500 Hz to 1 kHz)
  • Continuity Range/resolution: 600 Ω / 1 Ω
  • Continuity Accuracy: Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of500 μs or longer.
  • Ohms Range/resolution: 600.0 Ω / 0.1 Ω6.000 kΩ / 0.001 kΩ60.00 kΩ / 0.01 kΩ600.0 kΩ / 0.1 kΩ6.000 MΩ / 0.001 MΩ || 40.00 MΩ / 0.01 MΩ
  • Ohms Accuracy: 0.9% + 1 || 5% + 2
  • Diode test Range/resolution: 2.00 V / 0.001 V
  • Diode test Accuracy: 0.9% + 2
  • Capacitance Range/resolution: 1000 nF / 1 nF10.00 μF / 0.01 μF100.0 μF / 0.1 μF9999 μF / 1 μF100 μF to 1000 μF || > 1000 μF
  • Capacitance Accuracy: 1.9% + 2 || 5% + 20%
  • Lo-Z capacitance Range: 1 nF to 500 μF
  • Lo-Z capacitance Accuracy: 10% + 2 typical
  • AC amps True RMS (45 Hz to 500 Hz) Range/resolution: 6.000 A / 0.001 A10.00 A / 0.01 A
  • AC amps True RMS (45 Hz to 500 Hz) Accuracy: 1.5% + 320 A continuous overload for 30 seconds max
  • DC amps Range/resolution: 6.000 A / 0.001 A   10.00 A / 0.01 A
  • DC amps Accuracy: 1.0% + 320 A continuous overload for 30 seconds max
  • Hz (V or A input)² Range/resolution: 99.99 Hz / 0.01 Hz999.9 Hz / 0.1 Hz9.999 kHz / 0.001 Hz50.00 kHz / 0.01 Hz
  • Hz (V or A input)² Accuracy: 0.1% + 2

Mechanical and General Specifications

  • Size: 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
  • Weight: 550 g
  • Warranty: 3 years

Overview

UPC 09596932420
GTiN 00095969324205
Warranty Length 3 yr
Operating Temperature -10 To 50 C
Type Digital Multimeter
Battery Type NEDA 1604A / IEC 6LR61,9 Volt Alkaline
Applications Compact true-rms meter for commercial applications
Weight 550 g
Temperature Rating -10 to 50 C
Family Brand Name Fluke
Display Type Digital
Blade Dimensions 6.58 x 3.35 x 1.81 IN
Accuracy 0.5 % + 2 V
Enclosure Hard plastic
Resistance 0.1 O to 40 MO Ohm
Storage Temperature -40 To 60 C

Your Product Lists

Log In or register for an account to gain access to the product groups feature!

You can create lists of products for regular needs, special projects, even use one as a wishlist.

Your Part Numbers

Log In or register for an account to assign your company part numbers to products!